In the process of mechanization replacing manual labor, the application of concrete pump trucks in concrete construction has become commonplace.
In the process of mechanization replacing manual labor, the application of concrete pump trucks in concrete construction has become commonplace. Due to their convenient operation, super - standard pumping performance, and the elimination of cumbersome pipe - laying steps, they have been favored by many construction units.
However, during use, a customer's pump truck encountered the following fault: the boom operation malfunctioned when the pump truck was in remote - control mode. So, what exactly caused this kind of fault? Let's follow the technicians responsible for on - site fault handling to find out.
Fault phenomenon
In a pump truck, when using the HBC remote control, the near - and far - control during the first pumping was normal. After switching to the driving state, the near - control during the second pumping was normal. In the remote - control state, the forward and reverse pumps and mixing reversals functioned properly, but the boom operation failed.
Fault analysis
1. The remote - control lever is damaged and does not move. However, since the pumping is normal, this possibility can be ruled out.
2. The remote - control signal is not good or there is co - frequency interference. But considering that there are forward and reverse pumps and stirring reversals under remote control, this can be ruled out.
3. The forward and reverse pumps and stirring reversals are controlled by switch quantities and have no primary protection. The action of each arm, the speed of the arm's action, and the pumping displacement are proportionally controlled and have no secondary protection. The proportional control should return to the zero position in the natural state. Otherwise, the protection will self - lock, and all proportional controls will fail.
Troubleshooting process
After excluding the first two possibilities, open the remote - control box cover. There are two metal wires on the side of the fan - shaped gear that meshes with the gear corresponding to the remote - control rod. The position where the two metal wires are aligned is the zero - position mark. Use a 1.5mm hexagon wrench to loosen the fastening screw, pull the rocker to adjust until the two metal wires of the remote - control rod are aligned in the natural state (adjust to the normal zero position), and then tighten the screw. Thus, the fault is resolved.
In order to protect the life safety of the operator, JIUHE takes common safety controls into consideration in the early stage of product design. Therefore, when the equipment is operated in an abnormal state for a long time, the equipment will automatically trigger the protection self - locking function.
About Us:JIUHE specializes in researching, manufacturing, selling, and providing after - sales services for construction machinery. Its main products include trailer concrete pumps, concrete line pumps, concrete pump trucks, concrete placing booms, wet shotcrete machines, ladder lift trucks, and aerial lift trucks. Contacts: inquiry@jiuhezg.com, +86 - 18765912751
Preceding page
Other News
JIUHE Customized 49M Concrete Boom Pump Truck
JIUHE Heavy Industry is committed to providing practical concrete machinery solutions for customers worldwide.
Concrete Trailer Pump: Maximum Pumping Height, Distance, and Optimal Setup
Discover how high and far a concrete trailer pump can deliver concrete. Learn about pumping distance, pipeline design, concrete quality, and maintenance tips.
JIUHE 25m Ladder Lift Truck with Customized Alarm Function
We offer comprehensive customization services to meet your specific needs.
What to Do When a Concrete Trailer Pump Fails to Discharge? 7 Common Causes and Solutions
Why does a concrete trailer pump suddenly stop discharging concrete? What causes concrete pumping problems, and how can they be resolved?
How to Operate a Trailer Concrete Pump: 3 Stages
Learning how to operate a trailer concrete pump starts before the motor runs. Roughly ten minutes of checks prevents most of the failures that cost hours later. Work through them in this order.
Concrete Pump Truck Operator Safety: 5 Major Accident-Prone Areas to Monitor
Regardless of the type, all concrete pump trucks operate on the same fundamental principle, though there may be minor variations.
Potential hazards encountered during concrete pump truck pipeline blockages
Experiencing a pipe blockage in a concrete pump truck during construction is a major headache; it not only delays the project schedule and proves highly troublesome to resolve, but can even lead to dangerous situations.
What causes the S-tube in a concrete pump to fail to swing into the correct position?
Today, we will explore the underlying causes of this incomplete oscillation in the S-tube.
QUICK CONNECT
CONTACT US
National Marketing Hotline:
+86-18300251951
After-Sales Hotline:
+86053285580031
International Sales Hotline:
+86-18765912751
Contact Email:
inquiry@jiuhezg.com
Contact Address: